NDT equipment - Ultrasonic for maintenance

    Ultrasonic Flaw Detector MFD510

              

    Key features

    • Master-slave menu, shortcut key and digital swiftly knob.
    • High brightness EL LCD display, reading under outside strong light conditions.
    • Designed with high performance security-guarantee battery module, easy assembly.
    • Independent with off-line possibility.
    • Large capacity and high performance Lithium-ion battery, working above 8 hours.
    • Small size and light weight instrument.
      Can be hold by one hand, durable in use and leading industrial trend.
       

    Key features

    • Range
      0~ 9999mm (at steel velocity);
      range selectable in fixed steps or continuously variable.
    • Pulser
      Pike excitation with low, middle and high choices of the pulse energy.
      Pulse Repetition Rate: manually adjustable from 10 to 1000 Hz.
      Pulse width: Adjustable in a certain range to match different probes.
      Damping: 100Ω, 200Ω, 400Ω selectable to meet different resolution and sensitivity.
      Working modes: Single element, dual element and through transmission.
    • Receiver
      Real-time sampling at 160MHz high speed enough to record the defect information.
      Rectification: Positive half wave, negative halfwave, full wave and RF.
      DB Step: 0dB, 0.1 dB, 2dB, 6dB step value and auto-gain mode.
    • Alarm
      With buzzer and sound.
    • Memory
      Total 100 configuration channels store all instrument operating parameters plus DAC/AVG curve.
      Stored configuration data can be easily previewed and recalled for quick, repeatable instrument setup.
      Total 1000 datasets store all instrument operating parameters plus A-scan.
      All the configuration channels and datasets can be transferred to PC via USB port.
    • Functions
      Peak Hold: Automatically searching the peak wave inside the gate and hold it on the display.
      Equivalent diameter calculation: find out the peak echo and calculate its equivalent diameter.
      Continuous Record: Record the display continuously and save it to the memory inside the instrument.
      Defect Localization: Localize the defect position, including distance, depth and plane projection distance.
      Defect Sizing : Calculates the defect size.
      Defect Evaluation : Evaluates the defect by echo envelope.
      DAC : Distance Amplitude Correction.
      AVG : Distance Gain Size curve function.
      Crack measure : Measure and calculates the crack depth.
      B-SCAN : Displays the cross-section of the test block.
    • Real-time clock
      Real time clock for tracking the time.
    • Communication
      USB2.0 high-speed communication port.
    • Specifications
      Range: (0 ~ 9999) mm
      Bandwidth: (0.5 ~ 15) MHz
      Material Velocity: (1000 ~ 9999) m/s
      Dynamic Range: ≥ 32dB
      Vertical linear error: ≤ 3%
      Horizontal linear error: ≤ 0.2%
      Resolution:> 40dB (5P14)
      Sensitivity Leavings: 60dB (flat-bottomed deep hole 200mm–§2)
      Rejection: (0 to 80)%
      Linear Noise level: ≤ 10%
      Power supply: DC 9V; lithium batteries work for 4 to 8 hours or more.
      Ambient temperature: (-20 ~ 50) - Relative Humidity: (20 ~ 95)%RH
      Overall dimensions: 263 × 170 × 61 (mm).
    • MFD 510 Standard Configuration
      Main Body
      Straight Beam Probe
      Angle Probe
      Machine-probe Cable (Q9-Q9)
      Battery Module
      Power Adapter (Charger)
      Support Pillar
      Manual
      Instrument Case
      Datapro Software
      USB communication Cable
     

    The MFD150 is manufactured by:

    Stacks Image 2618
     

    Download the brochure (pdf).

     

     

    Contact Servicing Europe NDT bv for more information.

     

     

    Ultrasonic Flaw Detector EPOCH 600

              

    Key features

    • Designed to meet the requirements of EN12668-1
    • PerfectSquare™ tunable square wave pulser
    • Digital high dynamic range receiver
    • Eight digital filters for enhanced signal-to-noise ratio
    • 2 kHz PRF for rapid scanning
    • Knob or navigation pad adjustment configurations
    • Large, full VGA sunlight readable display
    • Long battery life, supporting lithium-ion or alkaline batteries
    • Standard dynamic DAC/TVG and onboard DGS/AVG
    • 2 GB MicroSD memory card for data transfers and storage
    • USB On-The-Go (OTG) for PC communication
    • Alarm and VGA outputs
    • Optional analog output.

    Features

    • General
      Weight:
      1.68 kg (3.72 lb), including lithium-ion battery
      Languages: English, Spanish, French, German, Japanese, Chinese, Portuguese
      Transducer connections: BNC or Number 1 LEMO
      Data storage: 50,000 IDs onboard, removable 2 GB MicroSD card (standard)
      Battery type: Single lithium-ion rechargeable standard
      Battery life: 12 h to 13 h (lithium-ion), 3 h (alkaline)
      Power requirements: AC Mains: 100 VAC to120 VAC, 200 VAC to240 VAC, 50 Hz to 60 Hz
      Display type: Full VGA (640 x 480 pixels) transflective color LCD, 60 Hz update rate
      Display dimensions: (W x H, Diag.) 117 mm x 89 mm, 146 mm (4.62 in. x 3.49 in., 5.76 in.)
    • Pulser
      Pulser:
      Tunable Square Wave
      PRF: 10 Hz to 2000 Hz in 10 Hz increments
      Energy settings: 100 V, 200 V, 300 V or 400 V
      Pulse width: Adjustable from 25 ns to 5,000 ns (0.1 MHz) with PerfectSquare™ technology
      Damping: 50, 100, 200, 400 Ω
    • Receiver
      Gain:
      0 to 110 dB
      Maximum input signal: 20 V p-p
      Receiver input impedance: 400 Ω ± 5%
      Receiver bandwidth: 0.2 MHz to 26.5 MHz at –3 dB
      Digital filter settings: Eight digital filter sets standard (0.2-10 MHz, 2.0-21.5 MHz, 8.0-26.5 MHz,
      0.5-4 MHz, 0.2-1.2 MHz, 1.5-8.5 MHz, 5-15 MHz, DC-10 MHz)
      Rectification: Full-wave, Positive Half-wave, Negative Half-wave, RF
      System linearity: Horizontal : ± 0.2% FSW
      Vertical linearity: 0.25% FSH, amplifier accuracy ± 1dB
      Reject: 0 to 80% FSH with Visual Warning
      Amplitude measurement: 0 to 110% full screen height with 0.25% resolution
      Measurement rate: Equivalent to PRF in all modes
    • Calibration
      Automated calibration:

      Velocity, Zero Offset
      Straight Beam (First Backwall or Echo-to-Echo)
      Angle Beam (Soundpath or Depth)
      Test modes :Pulse Echo, Dual, or Through Transmission
      Units: Millimeters, inches, or microseconds
      Range: 3.4 mm to 13406 mm (0.132 in. to 527.8 in.) @ longitudinal velocity in steel
      Velocity: 635 m/s to 15240 m/s (0.0250 in./μs to 0.6000 in./μs)
      Zero offset :0 to 750 μs
      Display delay: –59 mm to 13401 mm (–2.323 in. to 527.6 in.) @ longitudinal velocity in steel
      Refracted angle: 0° to 85° in 0.1° increments
    • Gates
      Measurement gates:
      2 fully independent gates for amplitude and TOF measurements
      Gate start: Variable over entire displayed range
      Gate width: Variable from Gate Start to end of displayed range
      Gate height :Variable from 2 to 95% full screen height
      Alarms: Positive and Negative Threshold, Minimum Depth (Gate 1 and Gate 2)
    • Measurements
      Measurement display locations:
      5 locations available (manual or auto selection)
      Gate 1: Thickness, Soundpath, Projection, Depth, Amplitude, Time-Of-Flight,
      Min./Max. Depth, Min./Max. Amplitude
      Gate 2: Same as Gate 1
      Echo-to-Echo: Standard Gate 2-Gate 1
      Other measurements :Overshoot (dB) value for DGS/AVG, ERS (equivalent reflector size) for
      DGS/AVG, AWS D1.1/D1.5 rating (D), Reject Value
      DAC/TVG: Standard
      DAC points: Up to 50 points, 110 dB dynamic range
      Special DAC modes: Custom DAC (up to 6 curves)
      Curved surface correction: Standard OD or Bar correction for Angle Beam measurements
     

    The EPOCH 600 is manufactured by:

    Stacks Image 2618
     

    Download the brochure (pdf).

     

     

    Contact Servicing Europe NDT bv for more information.

     

     

    Stacks Image 397

    Servicing Europe NDT bv


    P.O. Box 49
    4700 AA Roosendaal
    The Netherlands
    Email: sales@sendt.com
    Servicing Europe NDT bv
    Scherpdeel 30
    4703 RJ Roosendaal

    The Netherlands
    Tel. +31 (0)165 538 606
    Servicing Europe NDT bv
    Tel. +31 (0)165 538 606
    Email: sales@sendt.com
    Stacks Image 5849
    Stacks Image 5857